About this deal

The slime and mold also form because the ice-making process is exposed to the air. The air, is filled with many contaminants, including mold spores and bacteria that can lead to a dirty ice machine. Dust and clean the outside of the ice machine as necessary with mild soap and water. Wipe with a clean cloth afterwards. The wrench light signals the harvest season as well as the freezing cycle. This happens in 1-second intervals after three 35-minutes harvest cycles. If it stops working, this could be due to a number of reasons; The methods below are for cleaning and sanitizing the S-Series, Indigo Series, and NEO Series of Manitowoc ice machines. Items Needed

Efficient, functional and with a huge 45kg capacity ice bin, the Manitowoc NEO ice machine is an advanced, class leading ice maker designed to be used in the most demanding of commercial environments such as stadiums, canteens, educational establishments and large restaurants. The NEO provides crystal clear, dice shaped ice consistently whilst using less energy and water than other comparable ice makers in its class. Designed in conjunction with professional caterers, the Manitowoc includes a removable ice bin and air filter, making the unit easy to empty and clean, whilst the ice is easily accessible with the angled access door. Includes energy efficient “delay” mode, meaning ice production can be suspended as required, saving water, energy and money. E05: High-Pressure Control Opened – The high pressure cutout switch (HPCO) has opened three times in a 4-hour period. E03: Input Power Loss – When power to the Indigo ice machine has lost, the control board will log the event in the ELOG and determines the loss of power on power-up.The water filter is broken – The water filter might be too dirty or damaged. You’ll need to replace it. While these components are soaking, take the other half of the cleaning solution and clean all foodzone surfaces of the ice machine and bin. E25: Bin Level Probe Low Sensor Fault. Each thermistor reading is monitored continuously by using six-second average values. When a thermistor has a 6-second average value outside of the valid range for more than 10 continuous minutes, you will see this code. Safety limits are designed to shut down the machine when issues are present that could damage the unit. One safety limit is designed to shut down the machine if there is a long harvest. And the other is designed to shut down the machine if there is a long freeze cycle. The water temperature is too high – Ice machines require a cold water supply. Make sure there is not a hot water supply line into the machine.

Taking half of the sanitizing solution, fill a spray bottle with it and liberally coat the parts with the solution. If you are unable to work another device on the outlet, the ice machine may have blown a fuse or tripped a circuit breaker.Be sure to read and follow all directions and recommended mixture ratios as stated in your ice machine’s user manual. Once the water trough refills and water flows over the evaporator, you can then add the recommended amount of ice machine cleaner. An ice machine is a crucial kitchen gadget if beverages are the main part of your menu. As such an optimally performing ice machine is key to your success. Keep reading to learn how to maintain and troubleshoot your Manitowoc ice machine for optimal performance all year round. Manitowoc Ice Machine Not Making Ice

If the ice is thin at the top of the evaporator, continue reading for the solution further down in this post under the problem “shallow or incomplete cubes.” Manitowoc Ice Machine Keeps Running If your specific model ice machine is currently calling for a purge, there should be voltage to the valve. A dump valve is normally closed and will only open when voltage is applied. Manitowoc Ice Machine Not Pumping Water The water float valve and its filter screen are dirty. Either can cause shallow or incomplete ice cubes.The Manitowoc NEO Technician Handbook says that if switches aren’t working properly on the NEO touchpad, a reset and test will need to be performed. Disconnect power to the ice machine to reset the control board. Restore power to the machine about 10 seconds later and test out the switches again. If they still don’t work, run an Ohm test to see if the issue isn’t associated with the control board or wiring. Resetting Safety Limits on NEO Undercounter Machines Allow the water trough to refill until the water flows over the evaporator. This will take approximately 3 minutes. The maximum freeze time is 60 minutes on S-Series and Indigo machines and 45 minutes on NEO® models. The harvest cycle begins automatically after time maximum freeze time ends. The maximum harvest cycle time is 3.5 minutes for a single evaporator and 7 minutes for multiple evaporators. The water pump works by taking the water from the water trough, pushing up through the tubing, out and over the evaporator through the distribution tube. It’s important for the water pump to be strong enough to push an even flow of water, but not too strong to cause the stream of water to miss cascading down the evaporator. Simply unplugging the ice machine is the best way to turn it off. If you cannot unplug the ice machine, the next best course of action is to locate the breaker that your ice machine is on and turn it to “off”

It’s easy, disconnect the ice machine drain, careful not to make a mess. Start the ice machine and watch the water flow out of the ice machine. During the freeze cycle, once the compressor is on and water flows over the evaporator. Another potential reason the compressor to not start is the condensing unit is not receiving power. Losing the water that is supplied to the ice machine can also cause an empty water trough. This can be caused by a leaking dump valve or a water trough that is damaged or not properly installed. Add the recommended amount of Manitowoc Ice Machine Sanitizer to the water trough by pouring it between the evaporator and water curtain. Refer to your user’s manual for the proper amount to use. When your Manitowoc ice machine shuts down prematurely, it most likely is going off on what’s called a safety limit. On Q Series ice machines there are 2 different safety limits, that will help you diagnose the problem.This is not intended to be a full statement of your rights under the Consumer Contracts Regulations. Full details of your rights are available from your Local Authority’s Trading Standards Office. How To Return A Product Please note some larger products are delivered to kerb-side (the street outside your home), it is at the drivers discretion if they can deliver the item to another location on the property. E12: Curtain Switch Fault. The machine is set for ice making and remains in bin full condition for more than 24 hours. For added convenience, Neo’s trusty ice making machine will give an alarm when ice cubes are full or water is deficient, meaning you have less to worry about and can spend more time entertaining guests or relaxing with family. Features and Benefits